Skip to content

Unit Docker

Draft, to be verified. This manual is an early draft based on the product page. Some details are missing or still need checking.

Category
Eurorack Accessories · Alternative Front Panels
Hardware revision
v1.0
Unit Docker with the standard face out, a render: a black 26 HP 1U panel with UNIT DOCKER along the top, MORPH along the bottom, the long opening for your modules in the middle, a long slot at each end and a mounting slot in each corner

Unit Docker is an adapter for 3U modules. It holds up to 5 HP of them on their side, so they fit in a 1U row (Intellijel format). If you don’t have or want 1U modules for the 1U row of your Explorer Case, this is the perfect solution.

Fit one 5 HP module, or a combination of narrower modules that adds up to 5 HP. Unit Docker itself is completely passive: it’s a panel, with no electronics and no power of its own.

The face plate is reversible, with two looks. Both faces show UNIT DOCKER and MORPH: the standard face is black, and the artwork face adds a unique MORPH artwork. Choose the one you prefer.

Unit Docker with the artwork face out, a render: the same panel covered in the MORPH artwork, a branching cream texture on black, around UNIT DOCKER and MORPH
Item Details
Format 1U tile (Intellijel format)
Width 26 HP
Panel size 131.7 × 39.65 mm, 1.6 mm thick
Capacity 3U modules, up to 5 HP in total, mounted on their side
Opening 114 × 25.5 mm, for your modules’ circuit boards
Module mounting Two long slots, 122.5 mm apart (the 3U mounting-hole spacing), with screws and nuts
Depth None of its own. Your modules reach as deep behind the 1U row as they do in a 3U row
Power Passive. Unit Docker draws nothing, but your modules still need their power cables
Face plate Reversible: standard (black) or artwork (unique MORPH artwork). Both show UNIT DOCKER and MORPH
Compatible with Explorer Case, Intellijel 1U format
In the box Unit Docker, 8 × M3 screws (8 mm long) and 4 × M3 nuts

Unit Docker is passive, so it has nothing to connect to your case’s power. Your modules still need theirs: connect their power cables to the case as usual.

Your modules reach as deep behind the 1U row as they do in a 3U row. Check that your 1U row has room for them before you start.

  • 4 screws fix Unit Docker to the rails of your 1U row, through the slot in each corner.
  • 4 screws and the 4 nuts hold your modules: one screw and one nut through each of their mounting holes.

Fit your modules to Unit Docker first, then fit Unit Docker in your case.

  1. Hold Unit Docker with the face you want to show toward you.
  2. Turn your module on its side and pass its circuit board through the opening from the front, so the module’s panel sits against Unit Docker.
  3. Line up the module’s mounting holes with the two long slots, one at each end.
  4. Put a screw through each mounting hole and slot from the front, and tighten a nut on it from behind.
  5. To fit several modules, place them one above the other, up to 5 HP in total, and fit each one the same way.
  1. Connect your modules’ power cables to the case as usual.
  2. Fit Unit Docker in the 1U row like any 1U module, with a screw through each corner slot.

Take your modules off, turn Unit Docker over left to right, and fit them again. UNIT DOCKER stays along the top on both faces.

The panel is reversible, with a different look on each side. Both faces have the same opening and slots; only the artwork differs.

The standard face of the panel: UNIT DOCKER along the top and MORPH along the bottom, the long opening in the middle, a long module slot at each end and a mounting slot in each corner
The artwork face of the panel: the same opening and slots, with the MORPH artwork, a branching texture, all around UNIT DOCKER and MORPH

Unit Docker has no connectors. These are its openings:

Opening Where What it’s for
Opening, 114 × 25.5 mm In the middle Your modules’ circuit boards pass through it
2 long slots, 122.5 mm apart One at each end of the opening Screws and nuts through your modules’ mounting holes
4 corner slots One in each corner Screws to the rails of your 1U row

Unit Docker brings 3U modules into a 1U row, such as the 1U row of an Explorer Case. Once fitted, patch your modules exactly as you would in a 3U row.

Fit it across the whole opening, with a screw and a nut through each of its mounting holes.

Fit narrower modules one above the other, as long as they add up to 5 HP: for example a 2 HP and a 3 HP module, or a 1 HP and a 4 HP module.

Does Unit Docker need power? No. It’s a passive panel. Your modules still need their power cables, connected to your case as usual.

How many modules can I fit? As many as add up to 5 HP: one 5 HP module, or a combination of narrower ones.

Will my module fit? Its circuit board must pass through the 114 × 25.5 mm opening, and your 1U row needs room for the module’s depth, which is the same as in a 3U row.

Which screws go where? Four screws fix Unit Docker to the rails. The other four, with the four nuts, hold your modules. See Screws and nuts.

Can I change the face later? Yes. Take your modules off, turn Unit Docker over left to right, and fit them again. See Changing the face.

Which cases does it fit? The Explorer Case and any Intellijel-format 1U row.

Date Change
2026-10-29 Added the hardware revision, the panel size, opening and slots, what’s in the box, fitting your modules and Unit Docker, both faces of the reversible panel with their drawings and renders, usage examples and FAQ, from Federico’s answers.
2026-09-29 First draft, based on the product page, ModularGrid and Federico’s answers.

Report an error in this manual